PWRD51
Special point:
teflon rod antenna, suitable for small size interface installation.
Should use:
mainly used in the process of simple conditions, corrosive liquid, slurry level measurement.
(e.g. : sewage tanks, acid and alkali tanks, slurry tanks).
Maximum range: 20 m
Process connection: screw thread, flange
The process temperature: - 40 ~ 120 ℃
Process pressure: (-0.1 ~ 0.3)MPa
Fine degrees: ±8 mm
Reduplication: ± 2mm
Frequency range: 6.8GHz
Signal output: (4~20)mA/HART agreement (24V DC two-wire system/four-wire system)
(4~20)mA/HART agreement (220V AC four-wire system)
Explosion-proof grade: Exia IIC T6 Ga
Protection class: IP 67